Panic hardware door latching assembly incorporating a device which releases the latch upon application of a force in the direction of exit travel.
Exit door panic hardware requirements.
An exit door must be unlocked.
An applied force of 15 pounds should be enough to release the latch.
Some codes and standards require panic hardware to operate.
Where panic hardware is required the actuating portion of the device touchpad or crossbar must be at least half the.
Exit devices are required by building code and local fire departments for many public buildings.
Codes to know for panic hardware where panic hardware is required the actuating portion of the device touchpad or crossbar must be at least half the.
Such device must be a minimum of one half the width of the door in length.
For example this should not be less than 30 inches and not more than 44 inches above the floor.
You should never add a chain lock padlock an extra deadbolt or any electric latches or components that would delay the opening of an egress panic hardware equipped door.
Hardware consisting of bars that extend to at least half of the width of the door leaf.
Other requirements for panic hardware include.
Because of its durability and ease of use panic hardware is also commonly installed in places where it isn t required by code.
The actuating portion of the exit device needs to be at least half the width of the actual door.
Panic hardware used on balanced doors must be touchpad type and the touchpad must not extend more than half.
When panic hardware.
Panic hardware is an exit device which is tested for u.
A force of 15 pounds applied to the touch pad or cross bar must release the latch.
It should not require more than 15 pounds of force to unlatch it.
Buildings will not pass inspection if they are not up to the life safety code with door hardware.
2 hand activated door opening hardware shall be centered between 30 inches and 44 inches above the floor.
Current codes require panic hardware to be mounted between 34 inches and 48 inches above the floor.
Above all equip doors with panic hardware and fire exit hardware.
1 panic hardware shall cause the door latch to release when a force not exceeding 15 pounds is applied to the releasing device in the direction of exit traffic.
No more than 15lbs.
The maximum unlatching force shall not exceed 15 pounds.
However some codes have recently.
1910 36 d 1 employees must be able to open an exit route door from the inside at all times without keys tools or special knowledge.
A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.